SURFACE-SPOOL HANG-OFF
Hanger spool below the tree
No load on the old tubing; nipple profiles kept for future isolation.
Coiled-tubing strings run in live wells to restore gas velocity and unload liquids, with no rig on location.
APPLICATIONS
THE QUESTION IT ANSWERS
As reservoir pressure falls, gas velocity drops below the critical rate and liquids load up. A smaller-bore coiled-tubing string restores velocity, run and retrieved under pressure with no rig on location.
Candidate engineering comes first
HOW IT WORKS
TWO WAYS TO HANG THE STRING
SURFACE-SPOOL HANG-OFF
No load on the old tubing; nipple profiles kept for future isolation.
SUB-SURFACE HANG-OFF
Landed downhole on a high-load packer; the tree unmodified; a simpler operation where restrictions allow.
WHERE IT FITS
WHY IT PAYS · PUBLISHED SOURCES
US$7,000–64,000
Installed cost per well for +9,125–18,250 Mcf/well/yr; payback 0–3 years at US$3/Mcf, under a year at US$7.
12 days, 8 people
Rigless and live: 12 days with 8 people against at least 20 days and more than 50 people for a workover; no kill fluid.
> 5 MMscf/d
A well dead for two years came back at more than 5 MMscf/d and about 1,000 B/D condensate.
> 110 strings
In one Omani concession, and 39 in one field in four years, with a standard screening workflow.
PUBLISHED PAYBACK
EPA field case: two Gulf Coast wells at US$25,000 each, +25–50 Mcfd per well, 8-month payback, IRR 155%.
Results reported by operators and vendors in the sources listed below. They are third-party results, not Streamlines' own.
| Where · when | What was done | Published result | Source |
|---|---|---|---|
| Saudi Arabia · Saudi Aramco · 2015 | 10,000 ft 2⅜ in coiled-tubing string inside 4½ in tubing on a standing high-CGR gas well; rates from the test separator | Dead for 2 years → more than 5 MMscf/d at 1,900 psig FWHP with ~1,000 B/D condensate | SPE-172527-MS |
| Oman · PDO deep gas · 2023 | Velocity strings on liquid-loading wells suffering halite deposition after depletion compression | Field had lost ~40% of gas to halite; VS wells showed no further deposition, and bullheading and CT clean-outs were eliminated | SPE-213501-MS |
| Middle East · gas well, 9,160 ft · c. 2015–20 | 2⅜ in CT velocity string hung off below the SSSV on a live well; gauges later run inside it | 0–9 MMscf/d with more than 10 loading shutdowns in 9 months → ~6 MMscf/d without shutdown | Weatherford |
| USA · Gulf Coast · 2008 | Velocity tubing installed in two wells at US$25,000 each | +25–50 Mcfd per well; 8-month payback; IRR 155% | EPA Gas STAR |
No published Egyptian velocity-string case; SLB presented velocity-string deliquification at EGYPES 2025 and Streamlines has proposed it to Western Desert and Delta operators.
We run the critical-velocity screening on your measured rates and reply with whether a string pays.