REAL-TIMEREAL-TIME
Downhole gauges and real-time monitoring
Dual quartz pressure and temperature gauges in memory, surface read-out and wireless set-ups, feeding one dashboard.
- Sensors
- Dual quartz P and T
- Ratings
- 15,000 and 20,000 psi
- Calibration
- Every 6 months or 20 runs
- Configurations
- Memory, surface read-out, wireless
APPLICATIONS
Where it is applied
- Reservoir pressureRecorded downhole without a separate survey
- Build-up and drawdown testsIn memory, or read at surface
- Lift monitoringIntake pressure on gas-lifted and pumped wells
- Interference testsConnectivity between wells
- Gas wellsFlowing gradients and liquid loading
- High-pressure, high-temperature wellsGauges rated to 20,000 psi
THE QUESTION IT ANSWERS
What is the well doing between the monthly tests?
Surveillance turns well performance from monthly allocation into measured fact: pressures and temperatures recorded downhole, trended per well, at the wellsite and in the office.
Where the gauges are used
- Build-up, drawdown, static and flowing gradient surveys
- Flowing and shut-in pressure for transient analysis
- Oil, gas and injection wells with downhole or wireless surface sensors
- Loading, lift and decline problems that need to be seen early
REAL-TIME MONITORING
From the sensor to one dashboard
- 1Sense. Downhole and wireless surface sensors on oil, gas and injection wells.
- 2Collect. One SCADA dashboard for every well, field and facility.
- 3Analyse. Analytics for anomaly detection and trend prediction.
- 4Control. Closed-loop control of chokes, pumps and injection rates.
Why operators run them
- Independent measurementAllocation reconciled against it
- Early warningLoading, lift and decline problems seen early
- One place to lookData trended per well, at the wellsite and in the office
- Monitoring and controlChokes, pumps and injection rates adjusted in a closed loop
- Standard and HPHT15,000 and 20,000 psi ratings
- Hangers to suit the tubingBomb hangers for 2⅞, 3½ and 4½ in tubing
Service configuration
| Configurations | Memory tandem, surface read-out, wireless |
|---|---|
| Sensors | Dual quartz pressure and temperature |
| Ratings | Standard and HPHT, 15,000 and 20,000 psi |
| Calibration | Every 6 months or 20 runs |
| Hangers | Bomb hangers for 2⅞, 3½ and 4½ in tubing |
| Ancillaries | Bundle carriers, 24-, 40- and 60-arm calipers |
WHERE IT FITS
Measure, interpret, model, act
- MEASUREDownhole gauges with clamp-on flow and fluid-level surveys
- INTERPRETPressure- and rate-transient analysis on the recorded data
- MODELWell models calibrated to the measured pressures
- ACTLift, gas-lift and deferral decisions taken on measured fact
Name one well and one question.
We reply with the gauge configuration, rating and read-out that fit the well.