ISO 9001 · 14001 · 45001 certified · EGPC-registered
REAL-TIMEREAL-TIME

Downhole gauges and real-time monitoring

Dual quartz pressure and temperature gauges in memory, surface read-out and wireless set-ups, feeding one dashboard.

Sensors
Dual quartz P and T
Ratings
15,000 and 20,000 psi
Calibration
Every 6 months or 20 runs
Configurations
Memory, surface read-out, wireless

APPLICATIONS

Where it is applied

  • Reservoir pressureRecorded downhole without a separate survey
  • Build-up and drawdown testsIn memory, or read at surface
  • Lift monitoringIntake pressure on gas-lifted and pumped wells
  • Interference testsConnectivity between wells
  • Gas wellsFlowing gradients and liquid loading
  • High-pressure, high-temperature wellsGauges rated to 20,000 psi

THE QUESTION IT ANSWERS

What is the well doing between the monthly tests?

Surveillance turns well performance from monthly allocation into measured fact: pressures and temperatures recorded downhole, trended per well, at the wellsite and in the office.

Where the gauges are used

  • Build-up, drawdown, static and flowing gradient surveys
  • Flowing and shut-in pressure for transient analysis
  • Oil, gas and injection wells with downhole or wireless surface sensors
  • Loading, lift and decline problems that need to be seen early

REAL-TIME MONITORING

From the sensor to one dashboard

  1. 1Sense. Downhole and wireless surface sensors on oil, gas and injection wells.
  2. 2Collect. One SCADA dashboard for every well, field and facility.
  3. 3Analyse. Analytics for anomaly detection and trend prediction.
  4. 4Control. Closed-loop control of chokes, pumps and injection rates.

Why operators run them

  • Independent measurementAllocation reconciled against it
  • Early warningLoading, lift and decline problems seen early
  • One place to lookData trended per well, at the wellsite and in the office
  • Monitoring and controlChokes, pumps and injection rates adjusted in a closed loop
  • Standard and HPHT15,000 and 20,000 psi ratings
  • Hangers to suit the tubingBomb hangers for 2⅞, 3½ and 4½ in tubing

Service configuration

Bottom-hole pressure and temperature gauges
ConfigurationsMemory tandem, surface read-out, wireless
SensorsDual quartz pressure and temperature
RatingsStandard and HPHT, 15,000 and 20,000 psi
CalibrationEvery 6 months or 20 runs
HangersBomb hangers for 2⅞, 3½ and 4½ in tubing
AncillariesBundle carriers, 24-, 40- and 60-arm calipers

WHERE IT FITS

Measure, interpret, model, act

  1. MEASUREDownhole gauges with clamp-on flow and fluid-level surveys
  2. INTERPRETPressure- and rate-transient analysis on the recorded data
  3. MODELWell models calibrated to the measured pressures
  4. ACTLift, gas-lift and deferral decisions taken on measured fact

Name one well and one question.

We reply with the gauge configuration, rating and read-out that fit the well.

Plan a gauge programme