ISO 9001 · 14001 · 45001 certified · EGPC-registered
WELL TESTINGARTIFICIAL LIFT

Acoustic fluid-level and dynamometer surveys

Fluid level, dynamometer cards and producing BHP read from the wellhead with the Echometer Well Analyzer, with no intervention.

Reads
Fluid level, dynamometer, BHP
Deployed
From surface
Controlled by
TAM software
Intervention
None
Echometer survey at a wellhead: the analyzer case on the ground beside the pumping wellhead
Echometer survey at the wellhead

APPLICATIONS

Where it is applied

  • Rod-pumped wellsDynamometer cards, pump fillage and rod load
  • Fluid levelsProducing and static bottom-hole pressure with no gauge run
  • PCP wellsSubmergence and pump-off
  • Gas-lifted wellsAnnulus liquid level against valve depth
  • Gas wellsLiquid loading in the tubing
  • Build-up testsReservoir pressure from acoustic fluid levels

THE QUESTION IT ANSWERS

Is the rod-lift well pumped down, or pumped off?

The Echometer Well Analyzer is an integrated system for the acquisition and diagnosis of data in artificial-lift surveys. It reads fluid level, dynamometer cards and pressure together from the wellhead, so surveys run on producing wells with no intervention.

Every job closes with our engineers' interpretation and an action list, not a log print.

What it shows

  • Fluid level above the pump
  • Producing bottom-hole pressure
  • Pump fillage and rod loading
  • Pump and valve condition
  • Inflow data for lift design

Why operators run it

  • Simultaneous acquisitionFluid levels, dynamometer data and pressure recording together
  • Portable and lightweightEasy to handle, which makes data acquisition much simpler
  • Faster to installEasier navigation and optimized analysis options
  • No interventionSurveys run from surface on producing wells
  • Production at minimum expenseMaximizes oil and gas production with a minimum of operating expense
  • Pumped down, not pumped offKeeps rod-lift wells pumped down, with Echometer surveys and load-cell automation

WHERE IT FITS

Measure, diagnose, design, act

  1. MEASUREFluid level, dynamometer cards and producing BHP from surface
  2. DIAGNOSEPump fillage, rod loading, pump and valve condition
  3. DESIGNInflow data for the lift design
  4. ACTKeep rod-lift wells pumped down, not pumped off

WHY IT PAYS · PUBLISHED SOURCES

Lift on the well's own data

12–33%

On Egyptian field data, fluid-level-derived pump-intake pressure sits within 12–33% of measured values.

El-Saghier et al., J Pet Explor Prod Technol, 2020

Name one rod-lift well and one question.

We plan the survey with you and reply with the interpretation and the action list.

Plan an Echometer survey