ISO 9001 · 14001 · 45001 certified · EGPC-registered
DIAGNOSTICSLEAKS AND CROSSFLOW

Spectral noise and high-precision temperature logging

Tubing, casing, mandrel and packer leaks and behind-casing crossflow located by frequency and depth.

Locates
Leaks and flow, by depth
Works
Through tubing, behind barriers
Deployment
E-line or memory
Spectral noise log with a gas-lift mandrel leak and a tubing leak located by depth
Representative spectral noise log: gas-lift mandrel leak and tubing leak located by depth

APPLICATIONS

Where it is applied

  • Leak detectionTubing, casing and packer leaks located by depth
  • Sustained annulus pressureThe source and the flow path found
  • Flow behind casingChannels and cross-flow behind pipe
  • Barrier verificationBefore and after remedial work
  • Active zonesWhich intervals flow, including behind pipe
  • Injection conformanceOut-of-zone injection identified

THE QUESTION IT ANSWERS

Where exactly is the leak, and where is the flow going?

Flow through a leak, a channel or a perforation has an acoustic signature by frequency and depth. Spectral noise logging, paired with high-precision temperature and EM thickness, locates the failed barrier before anyone pulls the completion.

When to run it

  • Tubing, casing, mandrel and packer leaks
  • Behind-casing crossflow and channelling
  • The source of sustained annulus pressure
  • Mandrel leaks to be told apart from valve flow

Why operators run it

  • Found before the pullThe failed barrier located before anyone pulls the completion
  • Through tubingLeaks seen through tubing and behind several barriers
  • A targeted workoverLeak depth and path defined before anyone mobilises
  • Paired logsHigh-precision temperature and EM thickness read together with the noise
  • Mandrel or valveMandrel leaks told apart from valve flow
  • An action listOur engineers' interpretation and an action list, not a log print

WHERE IT FITS

Diagnose, define, act, record

  1. DIAGNOSESpectral noise, high-precision temperature and EM thickness in one campaign
  2. DEFINELeak depth and path set before anyone mobilises
  3. ACTA targeted workover, a patch or a bismuth-alloy barrier, then a WIT or SIT re-test
  4. RECORDBarrier status in the WelliRS register

WHY IT PAYS · PUBLISHED SOURCES

Find the leak before you mobilise

9.7 ml/min

Spectral noise detects leaks as small as this; high-precision temperature from about 6 l/h, both through tubing and behind several barriers.

SPE-190888-MS

Blind to targeted

Diagnosis first turns a blind workover into a targeted one: leak depth and path are defined before anyone mobilises.

TGT, case study CS025, India

10–30%

Of mature-field wells carry sustained annulus pressure in published surveys, so screening pays.

Schulz et al., J Pet Explor Prod Technol, 2025

Published case histories

Results reported by operators and vendors in the sources listed below. They are third-party results, not Streamlines' own.

Published case histories
Where · whenWhat was donePublished resultSource
UAE · ADCO · 2012HPT and spectral noise logging for sustained pressure in the B and C annuliTwo integrity failures located behind multiple barriers where conventional logs failedSPE-161983-MS
UK · Premier Oil, subsea · 2018EM thickness plus SNL/HPT through tubing to set envelope test values before P&A16% metal loss located in 9⅝ in casing; rig-based tubing retrieval avoidedSPE-190888-MS

No published Egyptian spectral-noise or EM-thickness case; the regional cases are from Abu Dhabi and the North Sea.

Name one well and one pressure.

We plan the logging run with you and return the located leak path with an action list.

Plan a leak-detection log