VENTURI–GAMMA
Venturi with single or dual gamma detection
Reads oil, gas and water rates in real time with no test separator, on 1.5 to 16 in lines. Truck-mounted or fixed.
Oil, gas and water rates read live at the wellhead: a venturi–gamma meter with no test separator, a smart float-type meter and a skid-mounted weighing meter.
APPLICATIONS
THE QUESTION IT ANSWERS
The multiphase meter is tied in on the flowline with a bypass, so the well keeps producing to the header while oil, gas and water rates are read live. Dual quartz gauges near the perforations record the flowing and shut-in pressures the transient analysis needs.
When to run it
HOW IT WORKS
THREE METERS
VENTURI–GAMMA
Reads oil, gas and water rates in real time with no test separator, on 1.5 to 16 in lines. Truck-mounted or fixed.
SMART MPFM
Measures oil, gas and water with a float-and-oscillation principle, with pressure and temperature on board, and a solar-powered RTU for remote sites.
MOBILE MPFM
Continuous gas–liquid measurement through the alternate operation of two separators, mobile or fixed. Suits thin oil, foamed crude oil and some heavy oils.
Commercial routes: campaign service with our crews, rental with operator support, or purchase with commissioning and training.
SMART MPFM · HOW IT WORKS
| Measurement medium | Multiphase fluid of oil, gas and water |
|---|---|
| Parameters | Liquid volume, gas volume, pressure, temperature |
| Flow measurement range | 0–5,032 bbl/day |
| Pressure range | Low: 0–363 psi; high: 363–3,626 psi |
| Temperature range | 50–302 °F |
| Accuracy | Liquid ±5%; gas ±10% |
| Measuring range | Water cut 0–100%; gas 0–5 MMscf/day; fluid 0–9,435 bbl/day |
|---|---|
| Nominal pressure | 360 psi, 580 psi |
| Accuracy | Liquid ±3.0%; gas ±5.0%; water cut ±2.0% |
| Working temperature | 41–176 °F |
| Explosion-proof class | Exd II BT4 |
| Signal output | Remote data transmission |
The same skid serves as a mobile test unit between wells or as a fixed meter on a station.
WHERE IT FITS
WHY IT PAYS · PUBLISHED SOURCES
US$0.1–0.25 M
A multiphase meter, against US$0.8–1.5 million for a test separator. Test flowlines add US$200–400k per km onshore.
≈ US$380,000 a year
Of mis-allocated revenue from a +2% water-cut bias on a 500 m³/d well.
±3–5%
Modern mobile meters hold oil and gas within ±3–5% of a separator, with 50% lower capex and up to US$550k saved per pad.
+650 b/d
After re-tuning one platform well: continuous rate data exposes gas-lift instability a separator cannot resolve.
EGYPT PRECEDENT
GUPCO tested seven gas-lifted October-field platform wells at 93–98% gas volume fraction with a multiphase meter in series with the separator: gas and liquid within ±10% at 93–96% GVF.
Results reported by operators and vendors in the sources listed below. They are third-party results, not Streamlines' own.
| Where · when | What was done | Published result | Source |
|---|---|---|---|
| Egypt · October field, GUPCO · 1998 | Non-intrusive MPFM in series with a test separator on seven gas-lifted wells, slugging to annular flow | Gas and liquid within ±10% of the separator at GVF 93–96%; liquid 1,300–4,700 B/D | Leggett et al., 1998 |
| Egypt · Western Desert, GUPCO · 2009 | Real-time production monitoring with pressure-transient data in a fractured carbonate with active water drive | Well production doubled inside the coning and erosion limits defined from the data | SPE-119361-MS |
| Canada · Torxen, Alberta · 2025 | Vx Spectra replacing test separators: 59 tests on seven wells under a regulator exemption | Oil within ±3% of separator; up to US$550,000 capex saved per new pad | SLB case study |
We reply with the meter, the gauges and the interpretation that fit the well.