ISO 9001 · 14001 · 45001 certified · EGPC-registered

DuraLift gas-lift valves

The valves decide where the lift gas enters. DuraLift unloading and operating valves are selected, set and changed out as one job with the gas-lift design, so the well lifts from the depth the design intends.

Valves
Unloading and operating (orifice) valves
Run in
Side-pocket mandrels, by slickline
Set from
The gas-lift design and the well model
Checked by
Nitrogen tracer and flowing surveys

APPLICATIONS

Where it is applied

  • New gas-lift completionsUnloading and operating valves set from the design
  • Valve change-outsLeaking, cut or mis-set valves replaced by slickline
  • Wells that multipoint or cannot unload to the design depth
  • Falling reservoir pressureThe injection point moved deeper
  • Changed water cut, rate or injection pressureValves re-sized
  • Wells short of drawdownPaired with the Supersonic Suction Tool

Is the well lifting from the depth the design intended?

A leaking, cut or mis-set valve lets gas in too shallow: the well multipoints, lift gas is wasted and drawdown is lost. The right valves, set at the right pressures, put the gas back at the operating point.

Valves, design and change-out as one job

Unloading and operating valves

Injection-pressure-operated unloading valves, and orifice valves for the operating point.

Spacing and set pressures

Mandrel spacing, port sizes and test-rack opening pressures from the well model.

By slickline

Valves pulled and set in the side-pocket mandrels with no workover.

Prove the result

A nitrogen tracer survey confirms the well lifts from the design point.

Diagnose, design, set, confirm

  1. 1Diagnose. Where the gas is entering today: tracer survey, pressures and the well model.
  2. 2Design. Valve type, port size and set pressures for today’s rate and water cut.
  3. 3Set. Valves calibrated on the test rack, then run by slickline.
  4. 4Confirm. The well unloaded, and the operating point checked against the design.

Name one gas-lifted well.

We reply with the survey and the design we recommend before any valve is changed.

Review a gas-lift well