ISO 9001 · 14001 · 45001 certified · EGPC-registered

Production engineering · Lift systems

Artificial lift — design, health check & troubleshooting

Every major lift system, covered end to end: designed for the well it serves, health-checked against its own design, and troubleshot to root cause — not to the first plausible symptom.

What we do

Gas lift

Valve spacing, sizing and type selection; optimum injection rate by sensitivity; unloading simulated and stability verified; system-level lift-gas allocation across the network.

Sucker rod / beam

Rod-string and pump sizing; dynamometer-card diagnostics; counterbalance and gearbox loading; pump fillage and pump-off control tuning for gassy and deviated wells.

Jet pump

Nozzle–throat sizing and power-fluid system design; cavitation screening; surface pump and fluid-conditioning requirements; a strong fit for sandy, deviated or remote wells needing rig-less retrieval.

Plunger lift

Liquid-loading screening for gas and high-GLR wells; plunger type and cycle design; controller logic tuning; combination with intermittent gas lift where reservoir pressure fades.

Unconventional & hybrid lift

High-pressure gas lift, gas-assisted plunger, rod-lift conversions for steep-decline wells — a lift strategy staged across the well's life, not a one-time selection.

Applications

Underperforming lifted wells · Short run lives and repeat failures · Unstable gas-lifted wells · Design checks before installation

More detail

Methodology — health check & troubleshooting

Baseline versus design → surveillance trending → diagnostics (sensor data, dyno cards, valve surveys, well tests) → root cause → corrective actions ranked by NPV — the same accountable workflow across every lift type, coupled to the well and network models.

Case study · anonymized

Multi-system lift health check across a mixed-lift field

Producing-field operator

The question

A field producing on rod and gas lift was losing barrels quietly — establish where each lift system stood against design, and what to fix first.

What we delivered

Well models rebuilt and matched; per-system diagnostics — pump sensor trending, dynamometer-card analysis, gas-lift valve surveys; root causes separated from symptoms; redesigns, conversions and controller-tuning actions ranked by NPV with the network response included.

Outcomes

  • 6 lift systems covered
  • Per-well diagnostics
  • NPV-ranked corrective actions

Share the question. We frame it with you.

A one-page problem statement is enough. A proposal with named experts, deliverables and acceptance criteria follows.

Talk to an engineer